Fyrite InTech Combustion Analyzer

Fyrite InTech® Combustion Analyzer
Hand-held Combustion Analyzer for Residential Applications
  • All-in-one instrument makes combustion tuning fast and simple with readings for O2, CO, CO2, combustion efficiency and temperature
  • Combustion App allows users to quickly create custom reports with comments and send via email (available for Android & iOS)
  • Automatic sensor protection helps technicians protect the analyzer in harsh environments, extending sensor life
  • IrDA printer allows technicians to reproduce combustion and emissions reports in the field
  • Ambient CO monitoring function allows technicians to check for dangerous CO levels
  • Quick and easy B-Smart® Sensor replacement in the field reduces downtime and doesn’t require calibration gas

 

 Description
The Fyrite® InTech® combustion analyzer is the perfect tool for entry-level and residential technicians who need to ensure safe operating conditions 
and determine combustion efficiency.  The InTech® features 6 fuels in the North American configuration to suit a wide variety of applications.
The InTech® includes sensors for O2 and CO, with an option for an external NOx filter.  The CO sensor can be replaced in the field without down time 
using B-Smart® pre-calibrated sensors.  The InTech® calculates values like efficiency, CO2 and CO air-free to help monitor combustion processes
effectively and accurately.
*Note: The Fyrite® InTech® calculates CO2 value based upon other measured values during the combustion process. It does not measure CO2 directly.
 Specifications
Measurements:				O2: 0 to 20.9%
					        CO: 0 to 2000 ppm
					        Stack temperature: -4 to 1202 °F (-20 to 650 °C)
					        Ambient air temperature: -4 to 212 °F (-20 to 100 °C)

Display					2.7 in. (69 mm) monochrome LCD w/backlight

Power					        4x AA batteries

Run Time					15 hours minimum (alkaline batteries)

Size (H x W x D)				8.0 x 3.6 x 2.3 in. (20.3 x 9.1 x 5.8 cm)

Weight					1 lb. (0.45 kg) including batteries

Fuels[1]					Natural gas, oil 2/6, kerosene, propane, butane, LPG, B5, KOKS, LEG, biofuel

Operating Conditions			23 to 113 °F (-5 to 45 °C), 15 to 90% RH (non-condensing), 1 ATM ± 10%

Warm-up Time				30 to 60 seconds

Memory					10 locations

Communications				USB 2.0 (mini-B), IrDA

Approvals					CE mark, EN 50379-1 & -3

Warranty					2 years (including sensors)

[1] Depending upon combustion equation setting (North American or Siegert) – see manual for details